Engineered systems for uptime and sustainability

Tools

Find the right pump and fix common alarms.

Use the pump finder to shortlist a set that fits your duty point, fluid, and application. Scroll down for the most common error codes and field fixes.

Open pump finder View error guide

What you need

  • Flow rate in liters per minute (LPM)
  • Required head or discharge pressure
  • Fluid type and any solids or chemicals present
  • Application: booster, irrigation, drainage, fire, process, or domestic

Need help? Call and we will size it with you on a quick call.

Pump finder

Send duty to us

We shortlist pumps using duty point, fluid, and application so you can quickly compare options.

Results

0 matches
Errors

Troubleshooting guide

Alarm cards come with every set. Use these steps to get online faster, then call us if a restart is not stable.

E01

What it means: Suction pressure dropped below safe threshold, usually due to clogged strainers or closed valve.

First actions: Clean suction strainer, confirm inlet isolation is open, and prime the pump before restart.

E05

What it means: Seal chamber temperature rising from dry run or blocked mechanical seal flush.

First actions: Check seal pot level, confirm cooling line is open, and verify the pump is flooded before start.

E09

What it means: Drive detected missing or reversed phase while the motor was running.

First actions: Verify incoming supply with a multimeter and check motor terminal block for loose conductors.

E12

What it means: Vibration sensor exceeded limit indicating misalignment or bearing wear.

First actions: Inspect coupling alignment, check for soft foot, and take a bearing temperature reading.

E21

What it means: Float or level transmitter reported unsafe level for pump operation.

First actions: Confirm level instruments are clean, test float travel, and review setpoints in the controller.

P009

What it means: Suction pressure dropped below safe threshold, usually due to clogged strainers or closed valve.

First actions: 1. Check suction strainer for blockages 2. Verify inlet isolation valve is fully open 3. Prime the pump before restart 4. Check for air leaks in suction line

Projects

A dynamic blend of visionaries and skilled professionals, our team combines engineering expertise, innovative thinking, and grassroots experience to deliver sustainable energy and smart agro solutions across Sri Lanka. From strategy to flawless project installations, every member shares a commitment to quality, sustainability, and community impact.